3-90-08691R17_11/13
Never sleep in the same room with any coal burning stove
Carbon Monoxide (CO) Awareness
Carbon monoxide, referred to as CO, is a colorless, odorless
gas that is produced during combustion of coal and other
fuels. CO fumes are toxic and can be fatal.
The TLC 2000 is a natural draft system which relies on
a properly designed chimney to remove CO and other
combustion by-products from the stove.
Even though this stove is designed to be as safe as possible,
it is important that you install a CO detector. This is true
for oil, gas, or wood as well.
CO is not specically heavier or lighter than air. Therefore,
it is best to install the detector at table top level rather than
on the ceiling like a smoke detector.
CO detectors are very sensitive and may sound an alarm for
fumes other than CO or CO from sources other than the stove
such as car or lawn mower exhaust.
If the alarm sounds
1. Increase ventilation by opening windows or doors.
2. Make sure the stove doors are closed and latched.
3. Check stove for normal operation.
4. Check for false alarm.
5. Have all occupants exit the building until the cause for the
alarm is discovered and/or remedied.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR “FRESHEN UP” A
FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE HEATER WHILE IT IS IN USE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS APPLIANCE.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM.
DO NOT USE CHEMICALS OR FLUIDS TO START THE
FIRE.
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS
SUCH AS GASOLINE, NAPTHA, OR ENGINE OIL
HOT WHILE IN OPERATION. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
WHEN INSTALLING IN A TIGHTLY CONSTRUCTED
HOME, A SOURCE OF FRESH AIR TO THE ROOM MAY
BE NECESSARY FOR PROPER OPERATION OF THIS
APPLIANCE.
CAUTION
!
FAILURE TO FOLLOW THE INSTALLATION
INSTRUCTIONS IN THIS MANUAL, OR USING
MAKESHIFT COMPROMISES DURING INSTALLATION
MAY RESULT IN PROPERTY DAMAGE, PERSONAL
INJURY OR EVEN DEATH.