Chimney System
Installing to a Prefabricated Chimney
WhenventingyourTLC2000usingaprefabricatedchimney,
be sure to contact local building code authorities, and to
follow the manufacturer’s instructions exactly. Use only
themanufacturer’sparts;donotusemakeshiftinstallation
techniques.Allprefabricated chimneysmustbetested to
eithertheU.S.orCanadianhigh-temperaturestandards,UL
103orULC-629.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
Existing Masonry Chimneys
Ifyouplanonusingapre-existingmasonrychimney,have
itthoroughlyinspectedandcleaned.Anyfaultswhichmake
thechimneyunsafeandunusablemustberepairedpriorto
use.Thesecanincludeimproperheight,structuraldefects,
blockages,inadequateclearancetocombustibles,unsealed
openingsintootherroomsofthehouse,signsofcreosoteor
smokeleakage,alooseorabsentclean-outdoor,orabsence
ofaliner.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM
Venting to a Masonry Chimney
Whenconnectingtoamasonrychimney,severalprovisions
arestandard.First,whetherthechimneyconnectorisvented
tothechimneythroughathimbleorabreechpipe,neither
must pass beyond the inner surface of the chimney liner,
andbothmustbermlycementedinplacewithrefractory
cement. (A thimble is a masonry pipe which is inserted
through the chimney wall, and is frequently the preferred
method;abreechpipeisapieceofsteelpipeusedthesame
way.)InCanada,abreechpipehasridgesorprotrusionsto
lockitrmlyintotherefractorycement.Ineithercase,the
chimneyconnectorventstothechimneythroughthethimble
orbreechpipe.
Usingathimble,theconnectorslidescompletelyinsidethe
masonrytotheinneredgeoftheueliner,andmaybeeasily
removed for chimney and connector inspection.A breech
pipemustextendatleast2"(50mm)intotheroom,sothe
connectorcanbeattachedwithsheetmetalscrews.
Venting to a Masonry Fireplace Chimney
Insomesituations,acodecompliantchimneyoriginallyused
for a masonry replace may be used to install your TLC
2000.Inadditiontotherequirementsfoundintheprevious
paragraphs,itisimportanttobeawarethatallclearances
mustbemet,includingthosefromthechimneyconnectorto
combustibles—18"(360mm)tosidesand18"(450mm)
toceiling. Donot forgetto includeoor protectionin your
plans.(SeeClearancesandFloorProtectioninthissection.)
Sincemanyreplaceshaveexposedwoodenmantelsand
trim,pay special attention tothe clearances necessary to
thesematerials.
Ifyourreplacechimneyisbehindacombustiblewall,you
must use an approved wall pass-through system to gain
access to the masonry chimney. The chimney connector
must enter the chimney at a place where it is lined, and
thereplacemustbe made inoperable.Forexample,you
mightremovethedamper,replacingitwithasecure,airtight,
noncombustible seal (removable for inspection); this also
satisestherequirementthatnoroomairmustbeallowed
toenterthechimney.
TheHarmanTLC2000wastestedwiththefueldooropen
andclosed.
If you operate with the door open, be sure to install the
optionalrescreen,andbesurethecleanoutcoverabove
thereboxisremoved.
Do not burn any fuel other than those specied. Other
solidfuels,suchascharcoal,cancauseincreasedcarbon
monoxideproductionoroverring.Neverusehighlyvolatile
substances in your stove, such as gasoline, which could
causeanexplosion.
When solid fuels are burned completely, they produce
waterandcarbondioxide.However,inlongslowburns,a
substantialamountofcarbonmonoxidemaybeproduced.
Ifallowedtobuildup,carbonmonoxide(whichisodorless)
canprovefatallypoisonous.Properventilationanddraftwill
prevent this from happening. If you smell smoke, turn up
the air control lever setting, and thoroughly ventilate your
dwelling. During future burns, be careful not to overload
thestovewithfuel,soyouwillnotbetemptedtoconstantly
operateatalowaircontrolsetting.
Othercausesofpoorventilationordraftareicing,exhaust
fans,ablockedoutsideairinlet,androomairstarvation.If
yourstoveissluggishandyougetoccasionalodor,check
thesepossibilitiesandincreasetheairowinyourhome.
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
Chimney
Connector
Clay thimble, reaching
just to the inside of the
chimney liner
Mechanical fasteners
(minimum 3) but not at the
bottom of the connector
Chimney liner
inner edges
High-temperature
sealant used to cement
the clay thimble
Kommentare zu diesen Handbüchern