3-90-08691R17_11/13
Chimney System
Installing to a Prefabricated Chimney
WhenventingyourTLC2000usingaprefabricatedchimney,
be sure to contact local building code authorities, and to
follow the manufacturer’s instructions exactly. Use only
themanufacturer’sparts;donotusemakeshiftinstallation
techniques.Allprefabricated chimneysmustbetested to
eithertheU.S.orCanadianhigh-temperaturestandards,UL
103orULC-629.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
Existing Masonry Chimneys
Ifyouplanonusingapre-existingmasonrychimney,have
itthoroughlyinspectedandcleaned.Anyfaultswhichmake
thechimneyunsafeandunusablemustberepairedpriorto
use.Thesecanincludeimproperheight,structuraldefects,
blockages,inadequateclearancetocombustibles,unsealed
openingsintootherroomsofthehouse,signsofcreosoteor
smokeleakage,alooseorabsentclean-outdoor,orabsence
ofaliner.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM
Venting to a Masonry Chimney
Whenconnectingtoamasonrychimney,severalprovisions
arestandard.First,whetherthechimneyconnectorisvented
tothechimneythroughathimbleorabreechpipe,neither
must pass beyond the inner surface of the chimney liner,
andbothmustbermlycementedinplacewithrefractory
cement. (A thimble is a masonry pipe which is inserted
through the chimney wall, and is frequently the preferred
method;abreechpipeisapieceofsteelpipeusedthesame
way.)InCanada,abreechpipehasridgesorprotrusionsto
lockitrmlyintotherefractorycement.Ineithercase,the
chimneyconnectorventstothechimneythroughthethimble
orbreechpipe.
Usingathimble,theconnectorslidescompletelyinsidethe
masonrytotheinneredgeoftheueliner,andmaybeeasily
removed for chimney and connector inspection.A breech
pipemustextendatleast2"(50mm)intotheroom,sothe
connectorcanbeattachedwithsheetmetalscrews.
Venting to a Masonry Fireplace Chimney
Insomesituations,acodecompliantchimneyoriginallyused
for a masonry replace may be used to install your TLC
2000.Inadditiontotherequirementsfoundintheprevious
paragraphs,itisimportanttobeawarethatallclearances
mustbemet,includingthosefromthechimneyconnectorto
combustibles—18"(360mm)tosidesand18"(450mm)
toceiling. Donot forgetto includeoor protectionin your
plans.(SeeClearancesandFloorProtectioninthissection.)
Sincemanyreplaceshaveexposedwoodenmantelsand
trim,pay special attention tothe clearances necessary to
thesematerials.
Ifyourreplacechimneyisbehindacombustiblewall,you
must use an approved wall pass-through system to gain
access to the masonry chimney. The chimney connector
must enter the chimney at a place where it is lined, and
thereplacemustbe made inoperable.Forexample,you
mightremovethedamper,replacingitwithasecure,airtight,
noncombustible seal (removable for inspection); this also
satisestherequirementthatnoroomairmustbeallowed
toenterthechimney.
TheHarmanTLC2000wastestedwiththefueldooropen
andclosed.
If you operate with the door open, be sure to install the
optionalrescreen,andbesurethecleanoutcoverabove
thereboxisremoved.
Do not burn any fuel other than those specied. Other
solidfuels,suchascharcoal,cancauseincreasedcarbon
monoxideproductionoroverring.Neverusehighlyvolatile
substances in your stove, such as gasoline, which could
causeanexplosion.
When solid fuels are burned completely, they produce
waterandcarbondioxide.However,inlongslowburns,a
substantialamountofcarbonmonoxidemaybeproduced.
Ifallowedtobuildup,carbonmonoxide(whichisodorless)
canprovefatallypoisonous.Properventilationanddraftwill
prevent this from happening. If you smell smoke, turn up
the air control lever setting, and thoroughly ventilate your
dwelling. During future burns, be careful not to overload
thestovewithfuel,soyouwillnotbetemptedtoconstantly
operateatalowaircontrolsetting.
Othercausesofpoorventilationordraftareicing,exhaust
fans,ablockedoutsideairinlet,androomairstarvation.If
yourstoveissluggishandyougetoccasionalodor,check
thesepossibilitiesandincreasetheairowinyourhome.
WARNING
!
DO NOT INSTALL IN SLEEPING ROOM.
Chimney
Connector
Clay thimble, reaching
just to the inside of the
chimney liner
Mechanical fasteners
bottom of the connector
Chimney liner
inner edges
High-temperature
sealant used to cement
the clay thimble