Floor Protection
In all installations, the area under and around the stove
mustbeprotectedfromfallingashandlivecoals.Theoor
protectormustbeofnoncombustiblematerial,andpositioned
asshownintheaccompanyingillustration.
The guidelines for oor protection are:
1. Completelyunderthestoveandanyhorizontalrunsof
connector.Theoorprotectionmustextendaminimumof
2"(51mm)beyondeachsideofthehorizontalconnector;
2. 8"(203mm)toeachsideandtotherearoftheappliance;
3. U.S.16"(405mm)infrontofthedoors; Canada18"(457
mm)infrontofthedoors.
Clearances
Clearanceistheemptyspacerequiredbetweenthestove
orchimneyconnectortothenearestcombustiblesurfaceor
object,suchaswalls,ceilings,oors,orfurniture.Clearance
distancesmayonlybereducedbyusingmethodsapproved
byeithertheCAN/CSAB365standard(Canada)orNFPA
211(U.S.)Contactyourbuildingauthorityforinformationif
youareinterestedinreducingclearancedistancesotherthan
thosepresentedhere.
Installation
Parallel versus Corner Installations
Aparallelinstallationisoneinwhichthebackandsidesof
thestoveareparalleltothewallsbehindandtothesideof
thestove.Acornerinstallationisoneinwhichthebackofthe
stoveispositioneddiagonallyacrossacorneroftheroom.
Eachinstallationrequiresitsownsetofclearances.
For parallel installations the required clearance distances
fromthestove are:18"(457mm) tothe side walland 16"
(405mm)tothebackwall.Fromthechimneyconnectortothe
rearwallmustbe18"(457mm),tothesidewall27"(685mm)
andtotheceiling,36"(914mm).Fireplaceinstallationsmust
meetthesesameclearancerequirements;specicallyfollow
theseguidelinesformantelandtrimclearances.
For corner installations, the clearance distances from
thestoveare12" (305mm) fromeachcornerof the stove
measuredstraighttothenearestcombustiblematerial.
Fromthefrontofthestove,clearancetocombustiblematerials
suchasfurniture,curtains,fuel,etc.,is:48"(1219mm)inthe
U.S.and60"(1524mm)inCanada.
Alternate oor protector dimension may be used as long
as they satisfy the measurement requirements shown
below.
Minumum size oor protection for a corner installation
hearth pad is 48" x 48" (USA ONLY).
48"
48"
J
G
Floor Protection
Requirements
Inches
Millimeters
Sides-USA/CANADA*
Rear-USA
8203
8305
H
Front-USA/CANADA*
16457
C
B
A
Parallel
Installation
Inches Millimeters
BackWallToUnit
SideWallToUnit
BackWallToFlueConnector
16406
18457
27685
Floor Protector
Wall
Wall
G G
H
J
A
B
C
F
E
Corner
Installation
Inches
Millimeters
WallstoUnitBody
WallstoFlueConnector
12305
18457
Floor Protector
Wall
Wall
E
E
F
F
Floor Protector